Flow Computers (FW)

The product group "Flow Computers" offers a unique range of comprehensive solutions to calculate the consumption and net flow at standard conditions or the ratio between two flows. Typical applications are found on board of ships to calculate the fuel consumption, gas flow calculation in power plants and the monitoring of two component blending.
The functionality of these products is based on the F1-Series hardware platform as multiple inputs are required for flow, temperature and pressure measurement.
All models are available for both safe area and hazardous area applications. Moreover, wireless data re-transmission and remote flow rate / totalizer monitoring is offered with the ProcessMonitor products and services .


The F126-EL flow computer has been developed to calculate corrected liquid volume at normal conditions. The corrected volumetric flow is calculated by measuring the uncorrected volumetric flow and actual line temperature which is processed with the thermal expansion coefficient algorithm stored in the flow computer. The reference temperature can be defined as desired (e.g. 15°C, 20°C or 60°F).

More details

The F126-EG flow computer has been developed to calculate corrected gas volume at normal conditions. The corrected volumetric flow is calculated by measuring the uncorrected volumetric flow, actual line temperature and pressure which are processed with the equations stored in the flow computer. A compressibility factor can be set to approach a real gas behavior.

More details

The F127 flow computer has been developed to calculate corrected differential liquid volume at normal conditions. This is calculated by measuring the uncorrected volumetric flow and actual line temperature in both the supply and return line. These signals are processed with the thermal expansion coefficient algorithm stored in the flow computer.

More details

The F114 flow computer calculates the actual ratio between two separate flows. It offers the ability to set one low ratio and one high ratio alarm value. Special precautions are taken to allow start-up problems and incorrect ratio readings for a certain period of time. Based on the location of the flowmeters, a selection can be made out of six different formulas.

More details

The F116 flow computer has been developed to calculate differential / consumption or total volume. The usual difficulties encountered in such applications include: pulsating flows, very low consumption readings, vibration and high ambient temperatures. These are all well catered for in the design and operation of the F116. The pulse and analog outputs do reflect the calculated differential or sum value.

More details
Back To Top