The product group "Flow rate / Totalizers" offers an extensive range of solutions from a basic totalizer up to a powerful flow rate monitor with flow curve linearization, flow rate monitoring, signal transmission, alarm and pulse outputs as well as full Modbus communication.
The functionality of this product group is based on two product series:
- E-Series: this is a range of user-friendly explosion proof indicators, totalizers and monitoring systems especially designed to be used in harsh and difficult hazardous area applications. It is beyond being just explosion proof. The E-Series have been certified according ATEX and IECEx by DEKRA with an ambient temperature of -40°C to +70°C (-40°F to +158°F). Its sturdy design and ease of use are unequaled by any other explosion proof indicator in the market!
- F-Series: this product range is supplied in a robust IP67 (NEMA4X) field mount enclosure and suitable for safe and hazardous area applications. The F-Series have been certified according ATEX and IECEx by DEKRA and according CSA c-us and FM for use in Intrinsically Safe applications. The F-Series is resistant to harsh weather conditions (rain, snow, salty atmospheres, temperatures between -40°C/-40°F and +80°C/+178°F) without use of expensive protective cabinets.
- D-Series: these products are supplied in a unique DIN panel mount casing and are only suitable for safe area applications. The robust IP66, IP67 (NEMA4X) front enclosure is made of die cast aluminum and is unequaled by any panel mounted indicator in the market: The D-Series is able to withstand total immersion and even powerful water jets!
The F010 is a local indicator with large 26mm (1\\\\\\\\\\\\\\\") high digits which displays the actual flow rate. The measuring and time units to be displayed below the flow rate are simply selected through an alphanumeric configuration menu. No adhesive labels have to be put on the outside of the enclosure: a weather proof and user-friendly solution!
More details
The F011 is a local indicator which displays the running total and accumulated total simultaneously. Total can be reset to zero by pressing the CLEAR button twice. The accumulated total can register up to 11 digits and is backed-up in EEPROM memory every minute, just as the running total. The measuring unit to be displayed is simply selected through an alphanumeric configuration menu.
More details
The F012 is our most popular model. This local indicator displays the actual flow rate, total and accumulated total. Total can be reset to zero by pressing the CLEAR button twice. The accumulated total can register up to 11 digits and is backed-up in EEPROM memory every minute, just as the running total.
More details
The D010 is a local, panel mount indicator to display the actual flow rate. The measuring and time unit to be displayed are simply selected through an alfa-numerical configuration menu. No adhesive labels have to be put on the outside of the enclosure: a weather proof and user friendly solution! The configuration of K-factors or Span and number of decimals is done through software functions, without any sensitive dip-switches or trimmers.
More details
The D011 is a local, panel mount indicator to display the running total and accumulated total. Total can be reset to zero by pressing the CLEAR button twice. A non-resettable accumulated total is available with eleven digits. The measuring unit to be displayed is simply selected through an alfa-numerical configuration menu. No adhesive labels have to be put on the outside of the enclosure: a weather proof and userfriendly solution!
More details
The D012 is a local, panel mount indicator to display the actual flow rate, total and accumulated total. The total can be reset to zero by pressing the CLEAR button twice. The eleven digit accumulated total however can not be reset to zero. The measuring unit to be displayed is simply selected through an alfa-numerical configuration menu.
More details
The F014 is a local indicator which displays the actual flow rate, total and accumulated total. A scaled pulse, related to the accumulated total is generated for re-transmitting the count on the display. Total can be reset to zero by pressing the CLEAR button twice. The accumulated total can register up to 11 digits and is backed-up in EEPROM memory every minute, just as the running total.
More details
The F016 is a local indicator which displays the actual flow rate, total and accumulated total. In addition to the average K-Factor or Span, eight linearization points can be entered with their frequencies or values. The unit will interpolate between these points, greatly enhancing accuracy in any flow range, even for very low frequency applications.
More details
The F110 is the most popular model in our range of flow rate / totalizers, complete with pulse and analog output signals. Even demanding applications are catered for with our base unit configuration. The display shows flow rate, total and accumulated total. On-screen engineering units are easily configured from a comprehensive selection.
More details
The F111 incorporates two flow rate / totalizers in one enclosure, including a pulse output for each flow. There is no relationship between the flows, even different pulse signal input types can be used. For each flow, on-screen engineering units are easily configured from a comprehensive selection.
More details
The F115 has been developed for applications where the direction of flow is an issue. It is required to offer two pulse signals from the flowmeter which are 90° or 270° degrees out of phase. In case of a reverse flow, the flow rate will be displayed as a negative value, the totalizers will count down and a switch output will be set. The pulse and analog outputs do reflect both flow directions.
More details
The D014 is a local, panel mount indicator to display the actual flow rate, total and accumulated total. The total can be reset to zero by pressing the CLEAR button twice. The eleven digit accumulated total however can not be reset to zero. Related to the acculmulated total, a scaled pulse is generated for re-transmitting the count on the display.
More details
The F013 is a versatile flow rate indicator and totalizer with continuous flow rate monitoring feature. It offers the ability to set one low flow rate and one high flow rate alarm value. If desired, an alarm ignore function can be set up to allow for an incorrect flow rate for a certain period of time. The display shows flow rate, total, accumulated total, alarm values and alarm messages.
More details
The F113 is a versatile flow rate indicator and totalizer with continuous flow rate monitoring feature. It offers the ability to set two low flow rate and two high flow rate alarm values. If desired, an alarm ignore function can be set up to allow for an incorrect flow rate for a certain period of time. Up to five outputs are available to transmit flow rate, alarm conditions and accumulated total.
More details
The F117 has been developed for applications where the totalized quantity has to be monitored and not the flow rate. When a start command is given, the totalizer is reset to zero. The amount of product measured from that moment is monitored continously for high totalizer values. Monitoring for low totalizer values will commence after a stop command is given or after a pre-defined time.
More details
The F118 is a versatile flow rate indicator and totalizer with the ability to precisely linearize the flowmeter signal. In addition to the average K-Factor or Span, ten linearization points can be entered with their frequencies or values. The unit will interpolate between these points, greatly enhancing accuracy in any flow range, even for very low frequency applications.
More details
The D013 is a versatile, panel mount flow rate indicator and totalizer with continous flow rate monitoring feature. It offers the facility to set one low flow rate and one high flow rate alarm value. If desired, a delay function can be set up to allow for an incorrect flow rate for a certain period of time.
More details
The F112 is a versatile flow rate indicator and totalizer with the ability to precisely linearize the flowmeter signal. In addition to the average K-Factor or Span, fifteen linearization points can be entered with their frequencies or values. The unit will interpolate between these points, greatly enhancing accuracy in any flow range, even for very low frequency applications.
More details
The D016 is a local panel mount indicator with linearization to display the actual flow rate, total and accumulated total. The total can be reset to zero by pressing the CLEAR button twice. The eleven digit accumulated total however can not be reset to zero. In addition to the average K-Factor or Span, eight linearization points can be entered with there frequencies or values.
More details
The F120 single loop controller has been designed to offer outstanding control performance and provide a reliable solution for a wide variety of flow control applications. The single loop flow controller accepts most pulse inputs from flow meters and has a 4 - 20 mA output for controlling a valve or pump. The F120 is part of the Fluidwell process controller family and is the alternative for local control loops.
More details

More details

The E110 is a popular model in our range of explosion proof flow rate indicators, complete with pulse and analog output signals. The E-series is distinguished by its high quality manufacturing and its functionality driven European design. We believe, it is not just about fulfilling the requirements for explosion proof, but it is about safety during daily operation. Ruggedness and reliability is where Fluidwell stands for and it is now available in a comprehensive well designed and purpose driven explosion proof flow rate indicator/totalizer.
More details
The E112 is a popular model in our range of explosion proof flow rate indicators. In addition to the average K-Factor, 16 linearization points can be entered. The unit will interpolate between these points greatly enhancing accuracy in any flow range. The E-series is distinguished by its high quality manufacturing and its functionality driven European design. We believe, it is not just about fulfilling the requirements for explosion proof, but it is about safety during daily operation. Ruggedness and reliability is where Fluidwell stands for and it is now available in a comprehensive well designed and purpose driven Explosion proof flow rate indicator / totalizer.
More details

Unequalled Safety and Ease of Use
Fluidwell introduces a new member to the E-Series family, the E115 explosion-proof bi-directional flow rate indicator / totalizer which detects the flow direction with quadrature signal inputs. Such applications can be found by loading and unloading of ships where one bi-directional flowmeter is used. Another application is the correction of back-flow due to shocks in a pipeline caused by piston pumps or valve behavior. It requires two pulse signals from the same flowmeter which are 90° or 270° degrees out of phase.
The E115 saves time, money and hassle; is designed to withstand the toughest conditions and is simple to use. Daily operations and plant operations for running work permit procedures are no longer interrupted and even (partial) plant shutdowns can be avoided as the covers do not need to be opened. Operating and setting the display functionalities is fast, safe and easy thanks to the through-glass keypad. This unequalled bi-directional flow rate indicator / totalizer delivers user-friendliness in the toughest conditions.
More details