
- Rosemount Tank Gauging
- Cameron
- Leakwise
- Siemens
- Precision Digital
- Scanjet
- Labkotec
- Enerac
- Contrec
- Berthold
- BWB Controls / Axelson
- Anderson Greenwood / AGCO
- ITT NeoDyn
- Graphic Controls
- Fuji Electric
- Fluidwell
- Xylem McDonnell Miller
- PKP Process Instrumentation
- Noshok
- Temperature Sensors
- Lauris Technologies
- Hitrol
- Radioactive Services In
- CS Instruments
- Bopp & Reuther
- RAE Systems, Inc.
- Emerson
- Supmea
-
Flow
-
Flow
- Paddle Type Flow Switch
- Paddle type flow switch with cable connection
- Paddle-bellows flow switch for liquids, with variable switching point
- Paddle-bellows flow meter and switch for liquids
- Flap Flowmeter and switch for low viscosity liquids
- Flap Flowmeter
- Paddle-bellows type flow switch with micro switch
-
Flow
- Flow Indicator with Wiper
- Rotor-type Flow Indicator
- Flow Indicator with Turbine
- Flow Indicator with Flanges
- Flow Indicator with Flap and Scale
- Ball type Flow Indicator
- Flow Indicator with Threaded Connection
- DG11 Flow Sight Glass with Flanged Connections
- Miniature Variable Area Flow meter and Switch
- Variable area flowmeter and switch with glass measuring tube
- Plastic Variable Area Flowmeter
- Float-Type Flow Meter For low flow volumes Compact construction
- Variable Area Flowmeter With Flange Connection, Insensitive To Viscosity Changes
- Piston Type Flow Switch for Low Flow Applications
- Flow
- Flow
- Flow
-
Flow
- SIEMENS SITRANS FUS 1010 (Standard) Ultrasonic Clamp-On Flowmeter
- SIEMENS SITRANS FUE 1010 (Energy) Ultrasonic Clamp-On Flowmeter
- SIEMENS SITRANS FUP 1010 (Portable) Ultrasonic Clamp-On Flowmeter
- SIEMENS SITRANS FUG 1010 (Gas) Ultrasonic Clamp-On Flowmeter
- SIEMENS SITRANS FUT 1010 (Liquid) Ultrasonic Clamp-On Flowmeter
- SIEMENS SITRANS FUT 1010 (Gas) Ultrasonic Clamp-On Flowmeter
- SIEMENS SITRANS FST 020 (Basic) Ultrasonic clamp-on flowmeters
-
Flow
- SIEMENS SITRANS FM MAG 3100 Flow Meter - Electromagnetic (sensor)
- SIEMENS SITRANS FM MAG 5100W Flow Meter - Electromagnetic (sensor)
- SIEMENS SITRANS FM MAG 1100 F Electromagnetic Flowmeter
- SIEMENS SITRANS FM MAG 1100 Electromagnetic Flowmeter
- SIEMENS SITRANS FM MAG 3100P Electromagnetic Flowmeter (Sensor)
- SIEMENS SITRANS FM MAG 5100 Ex d Electromagnetic Flowmeter(transmitter)
- SIEMENS SITRANS FM MAG 6000 Electromagnetic Flowmeter (transmitter)
- SIEMENS SITRANS FM MAG 6000 I/6000 I Ex de ELectromagnetic Flowmeter (transmitter)
- SIEMENS SITRANS FM Verificator Electromagnetic Flowmeter (Equipment tester for flowmeter)
- Flow
-
Flow
- SIEMENS SITRANS FCT 030 Coriolis/Density Flowmeter (Transmitter)
- SIEMENS SITRANS FC MASS 6000 Ex d Coriolis/Density Flowmeter(transmitter)
- SIEMENS SITRANS FC MASS 6000 Ex d Coriolis/Density Flowmeter(transmitter)
- SIEMENS SIFLOW FC 070 Ex d Coriolis/Density Flowmeter(transmitter)
- SIEMENS SITRANS FC S400 Ex d Coriolis/Density Flowmeter(transmitter)
- SIEMENS SITRANS FC S200 Ex d Coriolis/Density Flowmeter(Sensor)
- SIEMENS SITRANS FC MC 2 DN 50-150/ DN 20-80 (Hygienic) Ex d Coriolis/Density Flowmeter(sensor)
- SIEMENS SIEMENS SITRANS FC MASS 2100 DI 3-40 Ex d Coriolis/Density Flowmeter(sensor)
- SIEMENS SITRANS FC300 DN 4 Ex d Coriolis/Density Flowmeter(transmitter)
- SIEMENS SITRANS FC MASS 2100 DI 1.5 Ex d Coriolis/Density Flowmeter(sensor)
- Flow
-
Flow
- Liquid Flow Switches
- General Purpose Liquid Flow Switches FS 251 and FS 254
- FS 4-3T General Purpose Liquid Flow Switches
- FS 4-3 General Purpose Liquid Flow Switches
- FS 6-W High Sensitivity Liquid Flow Switches
- FS 1-W High Sensitivity Liquid Flow Switches
- FS 5 General Purpose Liquid Flow Switches
- FS 6 High Sensitivity Liquid Flow Switches
- FS 7-4E General Purpose Liquid Flow Switches
- FS 7-4 Industrial Liquid Flow Switches
- FS 7-4W Industrial Liquid Flow Switches
- FS 8-W Industrial Liquid Flow Switches
- Flow
- SIEMENS SITRANS DP Flow Transmitter
- Flow
- Flow
- Flow
-
Flow
- Low Water Cut off- Mechanical for Steam Boiler
- RB-122-E-Low Water Cut-Off
- RB-24E-Low Water Cut-Off
- RBT-3000 LWCO and Fuel Economizer
- RS-1-HP High Pressure Remote Sensor
- RS-1-LP Low Pressure Remote Sensor
- Series 21/221 Make-Up Water Feeders
- Series 25-A Make-Up Water Feeder
- Series 27-W Valve
- Series 47-2/247-2 Mechanical Water Feeder/LWCO
- Series 42S LWCO/Pump Controllers
- Series 47/247 Water Feeders
- Series 51/51-2 Mechanical Water Feeders/ LWCO
- Series 53/53-2 Mechanical Water Feeders/ LWCO
- Flow
- Cameron Flow Analysers
- Flow
- Flow
- Flow
- Flow
- Flow
- Flow
- Flow
- Flow
- Flow
- Flow
- Restriction Orifice
- Flow
- Flow
- Flow
- Electromagnetic Flow Meters
- Flow
- Cavitating Venturi
- Flow
- Flow
- Flow
- Flow
- Paddle Switches
- Flow
- Flow
- Bopp and Reuther coriolis flow meter
-
Flow
- Level
-
Pressure
- Precision Digital Pressure Gauges
- Pressure
- Pressure
- Pressure
- Pressure
-
Pressure
- 151P Low Differential Set Points (Explosion Proof)
- 152P Ultra Low System Pressure (Weather Proof)
- 160P Mid Range System Pressure (Weather Proof)
- 152P Ultra Low System pressure (Explosion Proof)
- 151P Low Differential Set Points (Explosion Proof)
- 160P Mid Range System Pressure (Explosion Proof)
- 162P High System Pressure (Explosion Proof)
- Pressure
- Pressure
-
Pressure
- 100P Internally Adjustable (Weather Proof)
- 101P Externally Adjustable (Weather Proof)
- 105P/105PP Minature Pressure Switch (Weather Proof)
- 110P Low Pressure Range (Weather Proof)
- 115P/115PP Built-To-Order (Weather Proof)
- 125P Higher Range Pneumatic Applications ( Weather Proof)
- 130P Adjustable Thru Port Cap-Pressure (Weather Proof)
- 131P Adjustable With Selectable Deadband-pressure (Weather Proof)
- 132P Pneumatic Or Low Impulse Hydrauic (Weather Proof)
- 142P Div 1&2 Hermetic-Ultra Low Range (Weather Proof)
- 200P Hydraulic Service-Internally Adjustable (Weather Proof)
- 201P Hydraulic Service-Externally Adjustable (Weather Proof)
- 225P High Pressure Hydraulic Applications (Weather Proof)
- 231P Adjustable Hydraulic Switch (Weather Proof)
- 232P High Pressure or High Impulse Hydraulic (Weather Proof)
- 100P Div 2/Terminal Strip (Explosion Proof)
- 100P Div 1 W/Terminal Strip ( Exposion Proof)
- 100P Div 1 & 2 hermetic (Explosion Proof)
- 110P Div 2 W/Terminal Strip- Low Range ( Explosion proof)
- 110P Div 1& 2 Hermetic- Low Range (Explosion proof)
- 112P ANSI Flanged Pessure Switch (Explosion Proof)
- 115P/115PP Build-To-Order Set Point (Explosion Proof)
- 122P CPI Pressure Switch (Explosion Proof)
- 123P Flush Welded Diaphragm (Explosion Proof)
- 125P higher Range Pneumatic Applications (Explosion Proof)
- 130P AdjustableThru Port Cap (Explosion Proof)
- 131PX Adjustable Selectable Deadband (Explosion Proof)
- 132P Universal Prssure Switch (Explosion Proof)
- 200P Div 1&2 Hermetic-hydraulic (Explosion Proof)
- 225P High Pressure hydraulic Applications (Explosion Proof)
- 231P Agjustable-Hydraulic (Explosion Proof)
- 232P High Pressure-Hydraulic (Explosion Proof)
-
Pressure
- 142P Ultra Low Vacuum (Explosion Proof)
- 142P Ultra LowVacuum (Weather Proof)
- 180P High System Pressure (Weather Proof)
- 181P Compact Vacuum Switch (Weather Proof)
- 182P Adjustabe Thru Port Cap (Weather Proof)
- 142P Ultra Low Vacuum (Explosion Proof)
- 181P Compact Vacuum (Explosion Proof)
- 182P Adjustable Thru Port Cap-Vacuum (Explosion Proof)
- Pressure
- Pressure
- Pressure
- Pressure
- Pressure
- Pressure
- Temperature
-
Tank Gauging System
- Tank Gauging System
-
Tank Gauging System
- Rosemount 5900C Radar Level Gauge
- Rosemount 5900S Radar Level Gauge
- Rosemount 5300 GWR Level Transmitters
- Rosemount 5400 Radar Level Transmitter
- Rosemount 565/566 Multiple Spot or Average Temperature Sensor
- Rosemount 2240S Multi-input Temperature Transmitter
- Rosemount 2410 Tank Hub
- Rosemount 2160 Field Communication Unit
- Rosemount 2230 Graphical Field Display
- Rosemount 2460 System Hub
- Rosemount 3051S Pressure Transmitter
- Rosemount 2120 Vibrating Fork Liquid Level Switch
- Rosemount 2130 High Temperature Level Switch SIL2
- SmartPower Solutions
- Tank Gauging System
- Tank Gauging System
-
Tank Gauging System
- RTG 3920 Horn Antenna Gauge
- RTG 3930 Parabolic Antenna Gauge
- RTG 3950 Still-pipe Array Antenna Gauge
- RTG 3960 LPG/LNG Gauge
- DAU2100 Data Acquisition Unit
- RDU40 Remote Display Unit
- MST - Multiple Spot or Average Temperature Sensor
- WLS - Water Level Sensor
- FCU 2160 - Field Communication Unit
- FBM 2180 - Field Bus Modem
-
Radioactive Instruments
- Radioactive Instruments
- Radioactive Instruments
-
Radioactive Instruments
- BERTHOLD LB565 Microwave Radiation Brix Measurement and Concentration Measurement
- BERTHOLD LB 566/567 Microwave Analyzer (Concentration and Water Content Measurement)
- BERTHOLD Carbon Content in Fly Ash (Combustion Analyzer)
- BERTHOLD MicroPolar Moist LB 568 System Highlights (Radioactive and Microwave measurement)
- BERTHOLD LB 350 Radiometric Moisture Measurement
- Radioactive Instruments
- Radioactive Instruments
- Recorders
-
Panel / Process Meters
-
Panel / Process Meters
- Fluidwell F050 Pressure indicator with very large digits with on-screen measuring units
- Fluidwell D050 Pressure indicator with very large digits
- Fluidwell F151 Dual input pressure indicator with separate engineering units for each input
- Fluidwell F053 Pressure monitor with one high / low alarm output
- Fluidwell F153 Pressure monitor with high / low alarms and analog outputs
- Fluidwell D053 Pressure monitor with one high / low alarm output
- Fluidwell F143 Temperature monitor with high / low alarms and analog outputs
-
Panel / Process Meters
- Fluidwell F040 Temperature indicator with very large digits
- Fluidwell D040 Temperature indicator with very large digits
- Fluidwell F141 Dual input temperature indicator with separate engineering units for each input
- Fluidwell F043 Temperature monitor with one high / low alarm output
- Fluidwell D043 Temperature monitor with one high / low alarm output
-
Panel / Process Meters
- Fluidwell F090 General purpose indicator input loop powered with very large digits
- Fluidwell D090 General purpose indicator input loop powered with very large digits
- Fluidwell F193 Modbus display with alarms, control and analog outputs
- Fluidwell F195 Valve Position Indicator VPI for hydraulic systems
- Fluidwell F197 Set-point generator with temperature input, alarms and analog outputs
- Panel / Process Meters
- Panel / Process Meters
-
Panel / Process Meters
- Fluidwell F126-EL Flow computer with temperature compensation for corrected liquid volume
- Fluidwell F126-EG Flow computer with temp & pressure compensation for corrected gas volume
- Fluidwell F127 Differential flow computer with temperature compensation for corrected liquid
- Fluidwell F114 Ratio monitor / totalizer with high/low alarms and analog outputs
- Fluidwell F116 Differential / sum flow computer with analog and pulse outputs
-
Panel / Process Meters
- Fluidwell F070 Level indicator with very large digits
- Fluidwell D070 Level indicator with very large digits
- Fluidwell F073 Level monitor with one high / low alarm output
- Fluidwell F077 Level monitor with linearization and one high / low alarm output
- Fluidwell F170 Level monitor with high / low alarms and analog outputs
- Fluidwell F173 Level monitor with linearization, high / low alarms and analog outputs
- Fluidwell D073 Level monitor with one high / low alarm output
- Fluidwell D077 Level monitor with linearization and one high / low alarm output
- Fluidwell F074 Level / pump controller with one control output
- Fluidwell D074 Level / pump controller with one control output
- Panel / Process Meters
- Flow Rate / Totalisers
- Panel / Process Meters
-
Panel / Process Meters
- PD6060: PROVU Dual-Input Process Meter
- PD6080: PROVU Modbus Scanner with Dual Analog Inputs
- PD6081: PROVU Feet & Inches Modbus Scanner with Dual Analog Inputs
- PD6088: PROVU Modbus Scanner
- PD6089: PROVU Feet & Inches Modbus Scanner
- PD6100: PROVU Strain Gauge, Load Cell & mV Meter
- PD603: Sabre P Low-Cost Process Meter
- PD865 Snooper Modbus Serial Input Meter
- PD6000: PROVU Process Meter
- Panel / Process Meters
-
Panel / Process Meters
- PDA 2301-2322: Economical Plastic NEMA 4X Enclosures for 1/8 DIN Instruments
- PDA2407-2415: Plastic NEMA 4X Enclosures
- PDA2501-2522: Plastic NEMA 4X Enclosures
- PDA2601-2622: Stainless Steel NEMA 4X Enclosures
- PDA2701-2722: Steel NEMA 4 Enclosures
- PDA2801-2821: Low-Cost Plastic NEMA 4X Enclosure
- PDA2901: NEMA 4X Enclosures for ConsoliDator
- PDA3407-3414: Economical Plastic Fully Sealed Enclosures
- Panel / Process Meters
- Panel / Process Meters
- Panel / Process Meters
-
Panel / Process Meters
- Fluidwell F030 Field mount - Batch controller with one-stage control
- Fluidwell F130 Field mount - Batch controller with two-stage control and pulse output
- Fluidwell F131 Batch controller with 2-stage control, pulse & analog o/p in relation to flow rate
- Fluidwell F132 Field mount-Batch controller with two-stage control and receipt printer driver
- Fluidwell F136 Batch controller with 2-stage control, pulse & analog o/p in relation to process
- Fluidwell D030 DIN Panel mount - Batch controller with one stage control
- Fluidwell N410 DIN Panel mount - Batch controller
- Fluidwell 310 Batch controller with numerical keypad and two-stage control
- Fluidwell 313 Batch controller with numerical keypad and direct ticket printing
- Fluidwell 320 Batch controller with numerical keypad, multiple preset values
- Fluidwell 326 Tanker loading computer with numerical keypad
- Fluidwell 330 Dual batch controller with numerical keypad
- Fluidwell F133 Delivery controller / Dispenser with pump start and valve control
-
Panel / Process Meters
- Fluidwell F010 Flow rate indicator with very large digits
- Fluidwell F011 Totalizer with on-screen measuring units
- Fluidwell F012 Flow rate indicator / totalizer displays flow rate and total simultaneously
- Fluidwell D010 DIN Panel mount - Flow rate indicator with very large digits
- Fluidwell D011 DIN Panel mount - Totalizer with all-weatherproof front enclosure
- Fluidwell D012 Flow rate indicator / totalizer displays flow rate and total simultaneously
- Fluidwell F014 Flow rate indicator / totalizer with pulse output
- Fluidwell F016 Flow rate indicator / totalizer with linearization and pulse output
- Fluidwell F110 Flow rate indicator / totalizer with analog and pulse outputs
- Fluidwell F111 Dual input flow rate indicator / totalizer with two pulse outputs
- Fluidwell F115 Bi-directional flow rate indicator/totalizer with analog, pulse & flow direction o/p
- Fluidwell D014 Flow rate indicator / totalizer with pulse signal output
- Fluidwell F013 Flow rate monitor/totalizer with one high/low alarm output
- Fluidwell F113 Flow rate monitor / totalizer with high/low alarms, analog & pulse output
- Fluidwell F117 Totalizer monitor with high / low totalizer alarms and analog output
- Fluidwell F118 Flow rate monitor/totalizer with linearization, high/low alarms, analog & pulse o/p
- Fluidwell D013 DIN Panel mount - Flow rate monitor / totalizer with high / low alarm output
- Fluidwell F112 Flow rate indicator / totalizer with linearization, analog and pulse outputs
- Fluidwell D016 Flow rate indicator / totalizer with linearization and pulse signal output
- Fluidwell F018 Flow rate monitor/totalizer with linearization,pulse/alarm & analog o/p and HART
- Fluidwell E018 Explosion proof-Flow rate/totalizer with HART Communication
- Fluidwell E110 Flow rate indicator / totalizer with analog and pulse signal outputs
- Fluidwell E112 Flow rate indicator / totalizer with linearization, analog and pulse outputs
- Fluidwell F120 Flow rate controller with analog control output and high / low alarms
- Fluidwell F124 Ratio controller with analog control output and high / low alarms
- Fluidwell E115 Explosion-Proof Bi-directional Flow rate Indicator / Totalizer
- Panel / Process Meters
- Panel / Process Meters
-
Panel / Process Meters
- Oil / Sludge Alarm
- Tank Cleaning
- Process Protection
- Valve Positioners
- Analysers
- Inst Valves - Manifolds
- Dosimeter
- Lithium Battery
- Calibrator
- Signal Generator
- 4-20mA Set-Point Generator
- Large Display Field Mount Indicators
- Control Stations

TankRadar Rex Tank Gauging System
- Highest accuracy for custody transfer/ inventory control
- Medium accuracy required primarily for operational control
A number of spot elements are placed at different heights to provide a tank temperature profile and an average temperature. Only fully immersed elements are used to determine product temperature. The MST can be integrated with a water level sensor.
The high quality and reliable Multiple Spot Temperature sensor (MST) measures temperature with a number of Pt-100 spot elements placed at different heights to provide a tank temperature profile and an average temperature.
Only the fully immersed elements are used to determine product temperature.
The spot elements are placed in a flexible gas tight protection tube made from convoluted stainless steel.
A flange can be attached to a top fitting and the tube can be anchored to the bottom.
The MST is easy to install, even if the tank is in service. In pressurized tanks the MST can be installed in a closed thermowell so that it can be removed for service or inspection while the tank is in operation.
For LPG tanks, single spot temperature sensors in thermowells are used.
Temperature sensors can be connected in two ways to the RTG:
- Directly into the RTG with common return connection (up to six temperature elements)
- Via the DAU (up to 14 temperature elements)
A water level sensor or a junction box can be integrated in the MST.
Highest reliability and custody transfer accuracy with up to 14 Pt-100 sensor elements
Available with 1/6 and 1/10 DIN B temperature accuracy class
-
Easy integration in Rosemount Tank Gauging System (sometimes connected directly into gauge)

The horn antenna gauge is designed for easy installation on 200 mm (8-in.) or larger nozzles on fixed roof tanks.
The horn antenna gauge is designed for easy installation on 200 mm (8-in.) or larger nozzles on fixed roof tanks. It measures on a variety of oil products except for asphalt and similar products for which the parabolic antenna gauge is recommended. RTG 3920 is delivered with a flange for straight installation or one for inclined installation. The inclined flange is used when the gauge is installed close to the tank wall and highest accuracy is required. Otherwise the straight flange is used. Installation is normally made without taking the tank out of operation.
- Highest accuracy for inventory and custody transfer on fixed roof tanks
- Curved-shaped, drip-off antenna design for enhanced reliability and precision
- TÜV-tested and approved for overfill protection according to WHG regulations
- Suitable for SIL 2 applications in accordance with IEC 61508/61511
- Inclined installation possibility when nozzle is close to the tank wall
- Possibility to install gauge with tank in operation

TankRadar Rex is designed for refineries, tank terminals and the petrochemical industry. It is the accurate system for custody transfer, process control, inventory control or for filling a tank without risk of overflow.
The RTG 3930 gauge is designed for installation on tanks with fixed roofs. It measures levels of products ranging from clean products to bitumen/asphalt. The design of the parabolic antenna gives extreme tolerance against sticky and condensing products.
- Highest accuracy for inventory and custody transfer on fixed roof tanks
- Drip-off antenna design with extreme tolerance against coating
- Even suitable for asphalt and bitumen
- TÜV-tested and approved for overfill protection according to WHG regulations
- Suitable for SIL 2 applications in accordance with IEC 61508/61511
- Possibility to install gauge with tank in operation

RTG 3950 with its small-sized array antenna is made for installation on existing still-pipes.
RTG 3950 with its small-sized array antenna is made for installation on existing still-pipes.
Typical applications are crude oil tanks with floating roofs and gasoline/product tanks with or without inner floating roofs.
To get custody transfer accuracy the gauge uses the Low Loss Mode, invented for the TankRadar products, to transmit the radar waves in the center of the pipe. This virtually eliminates degradation of the accuracy due to rust and product deposits inside the pipe.
RTG 3950 is available for 5-, 6-, 8-, 10- and 12-in. pipes.
There are two versions of RTG 3950; fixed and inclined. The inclined version has a hinged hatch, enabling full pipe size product sampling or verification hand-dips.
Installation is normally made without taking the tank out of operation.
- Highest accuracy for inventory and custody transfer on tanks with still-pipes
- Small-sized drip-off antenna design for increased reliability
- Low Loss Mode virtually eliminates accuracy degradation due to product build-up and rust
- TÜV-tested and approved for overfill protection according to WHG regulations
- Suitable for SIL 2 applications in accordance with IEC 61508/61511
- Possibility to install gauge with tank in operation
- Two versions available, fixed and inclined
- Inclined version with hinged hatch enables product sampling and verification hand-dips

The RTG 3960 gauge is designed for level measurement of liquefied gas in LPG or LNG tanks.
The RTG 3960 gauge is designed for level measurement of liquefied gas in LPG or LNG tanks. A still-pipe enables the gauge to have a sufficiently strong echo even under surface boiling conditions.
The radar signals are transmitted inside the still-pipe. The pressure sealing is a quartz/ceramic window approved for use in pressurized vessels. As an option the gauge is equipped with a fire-proof ball valve and a vapor space pressure sensor. The pressure sensor is required for highest accuracy.
A patented reference device function enables measurement verification with the tank in operation. A reference pin mounted in a still-pipe hole, and a deflection plate with a reflection ring at the lower pipe end provides measured distance values which are compared with stored positions.
Installation is made with the pressurized tank taken out of operation.
- Highest accuracy for inventory and custody transfer on tanks with liquiefied gas
- Antenna installed in 100 mm (4 in.) still-pipe, ensuring a strong echo even under surface boiling and turbulent conditions
- TÜV-tested and approved for overfill protection according to WHG regulations
- Suitable for SIL 2 applications in accordance with IEC 61508/61511

The Data Acquisition Unit (DAU 2100) is used together with an associated Radar Tank Gauge for local readout and for connection of temperature sensors.
The DAU is powered from, and communicates through the radar gauge to which it is connected. It is intrinsically safe using zener barriers on the Transmitter Interface Card (TIC) in the gauge.
<p style=""font-family:" tahoma;="" font-size:="" 12px;="" background-color:="" rgb(255,="" 255,="" 255);"=""> The weatherproof box houses a printed circuit board with a cable terminal for connection of the temperature sensors, as well as the power and communication cable. Cable glands are located at the bottom of the box.
<ul style=""font-family:" tahoma;="" font-size:="" 12px;="" background-color:="" rgb(255,="" 255,="" 255);"="">
- Handles up to 14 Pt-100 temperature inputs
- Level, ullage, spot & average temperature field display and analog input
- Excellent readability
- Easy to install and use
- Robust, weather/dirt protection
- Intrinsically safe

RDU 40 is a robust display unit for outdoor use in hazardous areas which can be connected up to 100 m (330 ft) from the gauge. If the number of temperature elements per tank is 6 or less, it is the most cost efficient field display.
RDU 40 is a robust display unit for outdoor use in hazardous areas. If the number of temperature elements per tank is 6 or less, the RDU 40 is the most cost effective solution for field display. In this case the temperature elements can be connected directly to the radar level gauge without using a Data Acquisition Unit (DAU).
It displays calculated data such as level, average temperature, volume, signal strength etc. Data can be displayed in lists or as single values, with a choice for the operator to have a user defined view.
<p style=""line-height:" 15pt;="" background:="" white;"=""> The RDU 40 is connected by a 3-wire cable up to 100 m (330 ft) from the gauge. Up to two units can be connected to the same TankRadar Rex gauge.

The water level sensor is used to determine the water content in a tank. At the bottom of an oil storage tank there is water and by measuring the water level it is possible to calculate the correct product volume in the tank.
The capacitive Water Level Sensor (WLS) continuously measures free water level below the oil surface and provides input for on-line net inventory. It is integrated with the Multiple Spot Temperature sensor (MST). The WLS is welded to the MST to get a hermetic design and it has no moving parts.
The WLS output is an analog 4-20 mA or digital HART signal, which is connected directly to a radar gauge.
There is a Pt-100 temperature sensor inside the probe, allowing measurements at low levels.
The WLS is welded to the MST to get a hermetic design. The open model WLS is suitable for crude oil applications and the closed model is suitable for lighter fuels such as diesel oil etc.
A junction box can be integrated with the WLS.
Measures interface between water and oil
-
Integrated with multiple spot temperature sensor or stand-alone for maximum flexibility
-
Highest reliability and custody transfer accuracy
-
Easy integration into Rosemount Tank Gauging System

The FCU polls data from Rosemount tank gauging field devices and stores the values in a buffer memory. When a request for data is received, the FCU can send data from up to 32 tanks.
- 2 field bus ports, 4 group bus ports
- RS232, RS485 and TRL2 Modbus communication possibility
- Redundant options for higher safety

The Field Bus Modem (FBM) is used for connecting a TankMaster PC to the TRL2 Bus.
Installation is performed using the mounting kit, included in all deliveries, which enables fitting of the FBM to a standard DIN rail.
- Increases the possible distance between an FCU and TankMaster PC
- Diagnostic LEDs on front cover
- Enables multidrop - one TankMaster can serve many FCUs via the FBM 2180
- Multiple installation options
- Enables FCU redundancy
